DESIGNS
- Home
- /
- DESIGNS
- THE CONTEXT
Understanding Orthokeratology
Orthokeratology (Ortho-K) uses reverse-geometry rigid lenses worn overnight to temporarily reshape the cornea, providing clear daytime vision without glasses or contact lenses. By inducing peripheral myopic defocus, it plays a key role in modern myopia management, particularly in pediatric patients.
Corneal Reshaping
Specialized lenses gently mold the corneal surface overnight to correct refractive errors without surgery.
Daytime Liberty
Enjoy total visual freedom during daily activities, sports, and swimming without the need for glasses or daytime contacts.
Slowing Progression
Clinically proven to reduce the elongation of the eye, significantly slowing down myopia in pediatric patients.
Safe & Non-Invasive
Unlike laser surgery, the effect is completely reversible; the cornea returns to its original shape if lens use is discontinued.
- Design
Design Philosophy
In orthokeratology, tear reservoir design directly influences lens centration, corneal reshaping efficiency, and visual outcomes. PAUNELENS focuses on precise control of tear reservoirs to ensure predictable, safe, and reproducible clinical results across different patient profiles.
Hydrodynamic Forces
Precise management of tear film pressure under the lens to achieve optimal.
Sagittal Accuracy
High-level control over sagittal depth to ensure a perfect match between the lens geometry and the corneal profile.
Predictable Results
Engineered designs that minimize clinical trial-and-error, delivering consistent and reliable visual performance.
Reproducible Fitting
A standardized logic that allows for easy replication of successful fittings across a wide range of patient topographies.
- PROVEN ORTHOKERATOLOGY
PAUNELENS 2R,Double Reservoir
The 2R design is our most established and versatile orthokeratology solution, featuring a strategic double-reservoir system. It is specifically engineered to provide exceptional stability and centration for standard to moderate myopia cases. This design has been clinically validated over years of practice, offering manufacturers a reliable, high-performance product that integrates seamlessly into any specialty lens portfolio.
- Double Reservoir System for optimized centration.
- Stable and Predictable results in standard myopia.
- Clinically Proven through years of successful fittings.
- Optimized for Efficiency and easy professional adaptation.
- PROVEN ORTHOKERATOLOGY
PAUNELENS 2R, Double Reservoir
The 2R design is our most established and versatile orthokeratology solution, featuring a strategic double-reservoir system. Specifically engineered to provide exceptional stability and centration for standard to moderate myopia cases, this design has been clinically validated over years of practice. It offers manufacturers a reliable, high-performance product that integrates seamlessly into any specialty lens portfolio, ensuring safety and efficiency.
- Micrometric control of fluorescein pattern.
- Optimal lens centration.
- Accelerated myopia reduction.
- Daytime freedom from lenses.
- NEXT-GEN TECHNOLOGY
PAUNELENS 3R, Triple Reservoir
The 3R design represents the pinnacle of our research in orthokeratology, introducing a sophisticated triple-reservoir system. This innovation allows for unprecedented control over hydrodynamic forces and sagittal precision, making it the ideal solution for complex corneal profiles and high-demand myopia management. It is a cutting-edge design developed for manufacturers who want to lead the market with the highest level of customization and clinical excellence.
- Enhanced control of aggressive myopia.
- Improved treatment alignment.
- Faster corneal molding.
- Easier-to-interpret fluorescein pattern.
- 2R vs 3R
2R vs 3R, Key Differences
2R
3R
Reservoirs
Double
Triple
Myopia Control
Standard
Enhanced
Fluorogram
Precise
More intuitive
Fitting Speed
Efficient
Faster
Adaptability
High
Higher
Innovation Level
Established
Next-generation
2R
Reservoirs: Double
Myopia Control: Standard
Fluorogram: Precise
Fitting Speed: Efficient
Adaptability: High
Innovation Level: Established
3R
Reservoirs: Triple
Myopia Control: Enhanced
Fluorogram: More intuitive
Fitting Speed: Faster
Adaptability: Higher
Innovation Level: Next-generation
- THE CONTEXT
KPCTP Fitting System
The KPCTP system is a distinctive fitting methodology shared by both 2R and 3R designs. It allows independent control of key parameters without affecting other zones, simplifying the fitting process while increasing clinical precision, safety, and predictability.
K — Corneal Reshaping
Manages central tear thickness and alignment to optimize reshaping efficiency.
TP — Target Power
Allows independent adjustment of refractive correction without altering the full design.
PC — Peripheral Control
Improves lens centration and stability through precise peripheral geometry.
- MANUFACTURING EXCELLENCE
Advanced Materials & Color ID System
PAUNELENS designs are manufactured using premium Acuity 200® and Contamac® materials, ensuring maximum oxygen permeability and exceptional mechanical stability for safe overnight wear. To further enhance clinical efficiency, we implement a specialized color identification system. By using distinct colors for right and left lenses, we simplify handling for the patient and reduce potential errors during daily practice, maintaining precise geometry and long-term dimensional consistency.
- High Oxygen Permeability (Dk) for superior corneal health.
- Exceptional Stability with Acuity 200® and Contamac®.
- Smart Color Coding for error-free lens identification.
- Consistent Geometry and long-term dimensional durability.
- 3R
3R: The New Innovative Design
A Unique Fluorescein Pattern
The 3R design generates a distinctive fluorescein pattern with three peripheral landing zones, enabling precise evaluation of peripheral alignment and simplifying clinical interpretation.
Designed for Maximum Myopia Control
3R includes flexible treatment options with two optic zone diameters to tailor peripheral defocus and treatment intensity.
Options:
MC (Advanced): 5.2 mm
MC+ (Enhanced): 4.7 mm
Built on Proven Sagittal Logic
The design is based on the KPCTP system, ensuring consistency, adaptability, and reliable clinical performance.
Clinical Coverage
3R supports a wide range of indications, including:
Myopia up to –7.00 D
Hyperopia up to +4.00 D
Astigmatism up to –5.00 D
Post-LASIK corneas
- Solutions
Distributor & Laboratory Solutions
Distribution Model
PAUNELENS lenses are manufactured by LCS (France) under strict quality
standards. The centralized production model ensures reproducibility, traceability, and consistent performance, allowing distributors to focus on market development and practitioner support.
Points:
– Controlled manufacturing
– Full traceability
– Regulatory compliance
– Stable clinical outcome
Manufacturing Model
Laboratories can integrate PAUNELENS designs into their own production systems. This includes access to specifications, validation protocols, and technical guidance to maintain sagittal accuracy and design integrity.
Points:
– Access to design parameters
– CNC integration support
– Validation guidelines
– Production control
- GET STARTED
Beyond Design: Tools for Clinical Application
PAUNELENS designs are supported by a complete ecosystem of professional tools, including fitting software, technical resources, and training materials. These solutions are developed to help practitioners apply our designs with precision, confidence, and efficiency in real clinical environments.